Conventional

Mild Steel

Pipe Welding

Low Hydrogen

Stainless Steel

Cast Iron

Hard Facing

Cutting & Gouging

Low Heat Input Welding Alloys

For Steels

For Disimilar Steels

For Cast Iron

For Stainless Steels

For Copper & Non Ferrous Alloys

For Nickel & Nickel Alloys

For HardSurfacing & Wear Resistant

For Cutting & Gouging

CCMS Wires


MIG/TIG Wires


Flux Cored Wires


SAW Wires & Flux


Welding Rectifier


Welding Transformer


Silver Brazing Wires


MIG/MAG Machines

Tuesday, September 07, 2010

Enquiry Cart (0) items

View Cart | Check Out

Home

The Company

Products

Process

Network

Feedback

Contact Us

Products Application

General Welding Safety

Storage of Welding Electrodes

I.S Classification (IS 814-04)

AWS-Classification

General Conversion Table

Properties of Metals & Alloys

En Series & Properties

Standard Casting Specification

Welding Defects & Remedies

MSDS



info@rasielectrodes.com

Keywords

e.g. Nickel based electrode

Select your Choice

 

Conventional  >>  Low Hydrogen Low Alloy and Creep Resistane Electrodes  >>  RASI E 11016 G

LOW HYDROGEN
RASI  E-11016 G

LOW ALLOY ELECTRODE

CLASSIFICATIONS
AWS-SFA 5.5 : E 11016 G IS : 1395 E 76 B G1 26

CHARACTERSTICS
RASI E 11016 G is a Medium heavy coated hydrogen controlled all position electrode giving Low Alloy Steel Weld metal with 2.6% Cr, 2% Ni, 1.2% Mo, 0.15% V giving a Tensile Strength of 960 N/mm2. The welds are Radio graphically sound and the third layered weld deposit hardness is up to 300BHN

APPLICANTIONS
RASI E 11016G is used for machinery parts made of High tensile strength steels, Earth moving equipments, forging dies, Automotive parts, chemical plants where Ni-Cr-Mo steels are used.

CHEMICAL COMPOSITION OF  ALL WELD METAL
ELEMENT C Mn Si Cr Ni Mo V S P
PERENTAGE 0.09 1.7 0.4 3.0 2.2 1.5 0.20 0.03 0.03

MECHANICAL PROPERTIES OF ALL WELD METAL

UTS (N/mm2) Ys (N/mm2) Elongation  %
960 880 16

Note: Single Values shown above are maximum

WELDING CURRENT AND PACKING DATA : AC 70 V / DC (+)
Dia (mm) 2.5 x 300 3.15 x 450 4 x 450 5 x 450
Current (A) 60-90 100-140 140-180 180-230
Pieces / Pkt 100 60 45 30
Pkts / Boxs 8 8 8 8

STORAGE
Re-dry the Electrode at 300°C for 1 Hr, use short arc during welding store the electrode in dry conditions.