Conventional

Mild Steel

Pipe Welding

Low Hydrogen

Stainless Steel

Cast Iron

Hard Facing

Cutting & Gouging

Low Heat Input Welding Alloys

For Steels

For Disimilar Steels

For Cast Iron

For Stainless Steels

For Copper & Non Ferrous Alloys

For Nickel & Nickel Alloys

For HardSurfacing & Wear Resistant

For Cutting & Gouging

CCMS Wires


MIG/TIG Wires


Flux Cored Wires


SAW Wires & Flux


Welding Rectifier


Welding Transformer


Silver Brazing Wires


MIG/MAG Machines

Friday, July 30, 2010

Enquiry Cart (0) items

View Cart | Check Out

Home

The Company

Products

Process

Network

Feedback

Contact Us

Products Application

General Welding Safety

Storage of Welding Electrodes

I.S Classification (IS 814-04)

AWS-Classification

General Conversion Table

Properties of Metals & Alloys

En Series & Properties

Standard Casting Specification

Welding Defects & Remedies

MSDS



info@rasielectrodes.com

Keywords

e.g. Nickel based electrode

Select your Choice

 

The company has a fully equipped quality control department to assess the quality of all incoming raw materials from various suppliers. They undergo stringent quality control inspection according to the laid down specification before they are cleared for production.
To carryout all these, our QC department is equipped with adequate testing facilities.
A brief description of the procedure that is being followed for inspection of incoming raw materials, in process inspection and finished product inspection is appended below.

1.0. Incoming Raw Materials

1.1. Steel
Electrode quality wire rods as per IS : 2879 received from TISCO / SAIL are delivered to the wire drawers premises located at Ambattur. The samples of rod coils with corresponding coil numbers are given to QC Lab for testing with heat numbers. The QC chemist records the details in the M.S-ROD / Wire Analysis Register. A numerical number in a serial manner is given (to denote the batch no) based on the number of consignments in a calendar year by respective wire drawers.

1.2. QC chemist arranges for testing as per inspection plan and records the test results viz: spark, etching, chemistry in M.S. Rod / Wire analysis register. The results are informed to the respective wire drawers.

1.3.
Only approved coils are taken up for drawing operation and in case of any rejection, the wire drawer is notified and such coil is delivered back to factory with its Weight Certificate by the wire drawer and the rejected coil number is verified by QC chemist. The rejected coil is then kept in a separate place and returned to the supplier.

1.4. The drawn wires in the form of coils are received in the goods receiving area with batch nos, coils & weight where the physical dimension and weight are checked by the Stores lncharge. They are then sent to QC lab by a memo for tests. The identification tags bearing the batch number and other details are tied to each coil.

1.5. The wires are then checked forepart, etching and chemistry and the test results are recorded in the wire test register.

1.6. The results are communicated and "|PASSED'' stamp is given on the respective tags of each coil.

1.7. Only passed drawn wires are issued for wire cutting operation.

1.8. The wires are straightened, cut to required length and stacked in pallet with proper identification and other details.

2.0 Powder Raw Materials & Silicates

2.1
On receipt of materials. stores informs QC Lab through a memo.

2.2.
QC chemist preserves the memo, records the details in the Raw Materials register and issues identification tags to the powder material, under inspection.

2.3.
Sampling and testing are done as per inspection plan and verified against respective raw material specification.

2.4.
Test results are recorded in the Raw Material Analysis Register.

2.5.
Test results are then communicated to store and the (Under Inspection) identification tag will be stuck with a PASSED STICKERS (Green in Colour)

2.6.
In case of silicates, passed stickers are stuck on the drums.

2.7.
In case of rejection, such bags / drums will be kept separately for further action with a ''Rejected / Tag / sticker'' (Red in Colour)

Reference Documents

1. Inspection plan (raw materials & steel)
2. Raw material specifications
3. Testing procedures
4. Is : 2879 (1975)

Records

1. M.S. Rod Wire Analysis Register
2. Raw Material Analysis Register
3. Suppliers Test Certificate

Tags

1. Raw Material Under Inspection Card (White)
2. Wire Cut Length (White)
3. M. S. Wire Tags (Green)
4. Green Sticker for “Passed”
5. Red Sticker for “Rejected”
6. Yellow Card for “Held up”

3.0 Inprocess Inspection

3.1.
Dry mixing is done as per formulation under the strict supervision of Quality Control supervision after mixing oversees unloading in bags with correct weight and puts an identification tag on each bag indicating the batch numbering date of mixing.

3.2.
Wet mixing is done under the direct supervision of production supervisor who ensures the correct quantity addition of silicates as per the requirements assuring the quality of the paste.

3.3.
The details are recorded in paste mixing register.

3.4.
He further oversees the following and records in the concentricity test registers as per the inspection plan during production (QC / DISP/O3).

1.Electrode Diameter

2. Electrode Length

3. Brush end

4. Concentricity of the coating

5. Striking end condition

6. General surface condition

3.5. The electrodes after production are kept in trays which are stacked in trolleys one over the other with proper identification tags.

3.6.
They are then kept for air drying over night for 6o13 types and 48 to 72 Hours for 7018 types and then lodged in to the drying / or baking oven as the case may be depending on nature of electrodes.

3.7.
The packing supervisor is responsible for drying and baking operation as per the parameters displayed.

3.8.
All the drying / baking details are recorded in the oven / Baking register.

3.9.
He also oversees the packing operation where he ensures the following as per parameters displayed.

1. Batch number & Date and other infestations.
2. Number of pieces per carton
3. Number of Cartons per box
4. Shrink wrapping of carton / Boxes

3.10.
Before he starts packing, he also ensures he coating moisture of the electrodes by testing in the QC Lab. If found OK, he will proceed with the packing.

Records

1. Paste Mixing Register
2. Concentricity-rest Register
3. Drying / Baking Register

Tags
Electrode Batch Number & Date Identification Tag (White)

Reference Documents
1. QC Display for drymixing
2. QC Display for wet mixing
3. QC Display for inprocess production parameters
4. QC Display for drying and baking
5. QC Display for standard method of packing

4.0. Finished Products Inspection

4.1 . The finished electrodes are subjected to the following tests before they are finally despatched to the customers.
(a) Welding performance tests in various positions for which the electrode is recommended for each batch.
(b) Coating moisture test for each batch.
(c) All weld metal chemistry
(d) All weld mechanical properties (All weld Tensile / impact)
(e) Metal recovery test where it is claimed
(f) Diffusible H2 test for LH electrodes

4.2.
The test welder is responsible for all the above activities and does everything as per the Inspection plan displayed given as annexure.

4.3.
All the results are verified against declared values of the product specification and recorded.

Reference Documents

1. QC Display for current / Amperes
2. QC Display for frequency of tests
3. Product specification brochures

Records

1. Welding performance reports
2. All weld metal chemical / mechanical Register
3. Daily moisture test register.

Top

Home   |   The Company   |   Process   |   Network   |   Feedback   |   Contact Us   |   Site Map

Design Global Trendz Technologies